OLYMPUS

Silicon cantilever for AC mode

TipView Design : for exact probe positioning
New Concept Chip : easy to handle with tweezers
Low Resistive Silicon : for anti-electrostatic charge

Silicon Nitride cantilever

Superior Durability and Small Spring Constant
Suitable for Contact mode and AC mode in water

Cantilever for Biological Sample Measurements in Water

Nanoscale Measurement
Force Curve Measurement
Observing Dynamic Behavior of Bio Sample in water


 



Product features

     Category of OLYMPUS micro cantilevers

Silicon cantilever for AC mode

TipView Design : for exact probe positioning
New Concept Chip : easy to handle with tweezers
Low Resistive Silicon : for anti-electrostatic charge

Silicon Nitride cantilever

Superior Durability and Small Spring Constant
Suitable for Contact mode and AC mode in water

Cantilever for Biological Sample Measurements in Water

Nanoscale Measurement
Force Curve Measurement
Observing Dynamic Behavior of Bio Sample in water

New Concept Chip

New Concept Chip

The ideally vertical side walls of the chip have two remarkable features.

1) Ease in chip handling

Vertical side walls provide larger contact area to grab the chip by tweezers compared with conventional trapezoidal chip cross section. You can grab the chip by tweezers with stability, and avoid the loss of chip by bungled handling. The “New Concept Chip” can save your chip cost.

2) Eliminate problems with chipping and debris

Chipping and debris of silicon chip would interrupt excitation of the chip by PZT when they are inserted between chip holder and chip. Vertical side walls can reduce the chipping and debris of silicon chip when grabbing the chip by tweezers.

TipView

TipView

The tip is located on the very end of the cantilever. This feature allows you to set the tip over a point of interest on the sample, easily and precisely, if you use an AFM combined with an optical microscope.

Point terminated tip

Point terminated tip

Point terminated tip

Point terminated tip

The tetrahedral shape is ideal for achieving a point terminated tip. In addition to the geometrical dimensions of the tip, the tip is further sharpened with our exclusive sharpening process.


    Product Line

  Produt name Resonance
Frequency 
(kHz)
Spring
Constant 
(N/m)
New Concept Chip TipView Design Measurement Environments Water Mode Measurement Environments Air Mode Measurement Modes Contact Mode Measurement Modes AC Mode Detection Signals Friction Measurement Detection Signals Force Curve Measurement
Silicon OMCL-AC55TS 1600 85      
OMCL-AC160TS 300 26        
OMCL-AC200TS 150 9        
OMCL-AC240TS 70 2        
OMCL-AC240TM 70 2      
Silicon nitride OMCL-TR400PSA 34 0.08        
11 0.02
OMCL-TR800PSA 73 0.57        
24 0.15
OMCL-RC800PSA 69 0.39      
18 0.05
71 0.76
19 0.10
OMCL-TR400PB 32 0.09      
10 0.02
OMCL-TR800PB 68 0.61      
22 0.16
OMCL-RC800PB 64 0.42    
17 0.06
66 0.82
17 0.11
BioLever BL-RC150VB 37 0.03        
13 0.006
BL-AC40TS 110 0.1            
BL-AC10FS 1500 0.1          
BL-AC10DS 1500 0.1          

 

 


產品細部說明: http://probe.olympus-global.com/manual/en.html

 

說明 檔案大小 下載
OLYMPUS-AFM 原子力顯微鏡探針 型錄 123KB
型號 概述 詢價數量